S/FTP CAT 8
S/FTP CAT 8

Application:
· 10G / 25G / 40G Ethernet transmission
· Test bandwidth of up to 2000MHz
Reference Standards
· IEC 60332-1 · IEC 60332-3-24 · EN50399
Testing Standards
· ISO/IEC 11801-1 · ISO/IEC 11801-2 · IEC 61156-9
· EN 50173-1 · EN 50173-2 · EN 50288-12-1

Physical Parameters:

Conductor Solid Bare Copper, 24AWG
Insulation Materials Skin-foam-skin Polyethylene
Insulation Diameter 1.45mm Nom. (CAT 8.1)
1.53mm Nom. (CAT 8.2)
PIMF Aluminum Foiled
Braided Shielding Tinned copper coverage 60%
Jacket Diameter 8.0mm Nom. (CAT 8.1)
8.8mm Nom. (CAT 8.2)
Jacket Diameter PVC or LSZH (depending on the jackets)
Compliant with RoHS and REACH

Electrical Parameters(20℃ ):

Transmission Delay Skew 25ns / 100m
Transmission Speed 78%
DC Conductor Resistance 6.92 / 100m
DC Conductor Resistance Unbalance 2%
Unbalance to Ground Capacitance  160pf / 100m